m8-connector-and-cable

Connector M12, M8 selection reference standard

Connector M12, Connector M8 selection reference standard

1.Select the sensor connector model according to the measurement object and measurement environment

To carry out a specific measurement work, we must first consider what kind of sensor connector principle to use, which can only be determined after analyzing many factors. Because, even if it is measuring the same physical quantity, there are multiple sensor connectors available for selection.

Which principle M8 or M12 sensor connector is more suitable, you need to consider the following specific issues according to the characteristics of the measured and the use conditions of the sensor connector: the size of the range, the requirement of the measured position on the volume of the sensor connector, and the measurement method Contact type or non-contact type, signal extraction method, wired or non-contact measurement, source of connector domestic or imported, whether the price is affordable, etc. After considering the above issues, we can determine which type of sensor connector to use, and then consider the specific performance indicators of the sensor connector.

2.Accuracy consideration of sensor connector

Accuracy is an important performance index of the sensor connector, and it is an important link related to the measurement accuracy of the entire measurement system. The higher the accuracy of the sensor connector, the more expensive it is. Therefore, the accuracy of the sensor connector only needs to meet the accuracy requirements of the entire measurement system, and it is not necessary to choose too high.

If the measurement purpose is for qualitative analysis, select a sensor connector with high repeatability accuracy. It is not advisable to use a high absolute value accuracy; if it is for quantitative analysis, accurate measurement values ​​must be obtained, and the accuracy level must be selected to meet the requirements. Connector.

3.Linear range of sensor connector

The linear range of the sensor connector refers to the range where the output is proportional to the input. In theory, the sensitivity remains constant within this range. The wider the linear range of the sensor connector, the larger the measuring range, and a certain measurement accuracy can be guaranteed. When selecting a sensor connector, when the type of sensor connector is determined, first see whether its range meets the requirements.

But in fact, no sensor connector can guarantee absolute linearity, and its linearity is also relative. When the required measurement accuracy is relatively low, within a certain range, the sensor connector with less nonlinear error can be approximately regarded as linear, which will bring great convenience to the measurement.

m8-connector-and-cable

m8-connector-and-cable

4.Sensitivity consideration of sensor connector

Generally, within the linear range of the sensor connector, it is hoped that the higher the sensitivity of the sensor connector, the better. Because only when the sensitivity is high, the output signal value corresponding to the measured change is relatively large, which is conducive to signal processing. However, it should be noted that the sensitivity of the sensor connector is high, and external noise that is not related to the measurement is also easy to mix in, and it will also be amplified by the amplification system, which affects the measurement accuracy. Therefore, it is required that the sensor connector itself should have a high signal-to-noise ratio, and try to reduce the factory interference signal introduced from the outside.

The sensitivity of the sensor connector is directional. When the measurement is a single vector, and its directionality is higher, you should choose a sensor connector with less sensitivity in other directions; if the measurement is a multi-dimensional vector, the sensor is required to connect The cross sensitivity of the filter is as small as possible.

5.Consideration of the stability of the sensor connector

The ability of a sensor connector to remain unchanged after a period of use is called stability. In addition to its structure, the factors that affect the long-term stability of the sensor connector are mainly the use environment of the sensor connector. Therefore, to make the sensor connector have good stability, the sensor connector must have strong environmental adaptability.

Before selecting a sensor connector, investigate its use environment, and select the appropriate sensor connector according to the specific use environment, or take appropriate measures to reduce the impact of the environment. The stability of the sensor connector has a quantitative index. After the use period has expired, it should be re-calibrated before use to determine whether the performance of the sensor connector has changed.

In some occasions that require the sensor connector to be used for a long time but cannot be easily replaced or calibrated, the stability of the selected sensor connector is more stringent and must be able to withstand the test for a long time.

6.Frequency response characteristics of sensor connector

The frequency response characteristic determines the frequency range to be measured, and the measurement conditions must be kept undistorted within the allowable frequency range. In fact, the response of the sensor connector always has a fixed delay, and it is hoped that the delay time is as short as possible.

The frequency response of the sensor connector is high, and the measurable signal frequency range is wide. Due to the influence of the structural characteristics, the inertia of the mechanical system is larger, and the frequency of the measurable signal is lower due to the low-frequency connector. In dynamic measurement, the response characteristics should be based on the characteristics of the signal (steady state, transient state, random, etc.) to avoid excessive errors.

0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply